T40 II

SINGLE GAS MONITOR

Enquire Now

about T40 II

• Robust, compact, and light

• Fast sensor response

• Multiple sensor range options with high accuracy

• Replaceable battery with two-year runtime

The T40 II single gas monitor is primarily used to protect personnel lives by detecting the presence of hydrogen sulfide or carbon monoxide.

The T40 II instrument is robust and light, with an IP68 level of ingress protection, and is suitable for working in changing, hazardous environment. The industry-leading ultra-fast T90 response time can detect gas hazards on the job in real time to ensure worker safety, saving valuable time. To meet the needs of long-term operation, the high-performance lithium battery can operate under extreme weather conditions continuously for two years.

There are two visual red alarm LEDs, in addition to both an audible and vibration alarm when the gas concentrations exceed the high, low, TWA, or STEL alarm preset values.

COMMON INSTRUMENT CONFIGURATIONS

PART NUMBER - DESCRIPTION

  • T42-014211 CO, 1000 PPM, Orange
  • T42-015211 CO, 2000 PPM, Orange
  • T42-021211 H2S, 100 PPM, Orange
  • T42-022211 H2S, 200 PPM, Orange
  • T42-023211 H2S, 500 PPM, Orange

Specification:

SPECIFICATIONS

  • INSTRUMENT WARRANTY T40 II monitor carries a two-year warranty from the date of shipment and is supported by Industrial Scientific Corporation (excludes batteries, clips, calibration caps and filters). CO and H2S sensors are warranted for two years.
  • DISPLAY Segment LCD
  • KEYPAD Two buttons
  • CASE MATERIALS Polycarbonate with a protective rubber over-mold
  • ALARMS Visual (two red LEDs); Audible (95db); Vibration, TWA, STEL
  • DIMENSIONS 82 x 60 x 27 mm ( 3.23" x 2.36" x 1.07" )
  • WEIGHT 85g (3oz)
  • INGRESS PROTECTION IP 66/68
  • TEMPERATURE RANGE -40 °C to 50 °C (-40 °F to 122 °F)
  • HUMIDITY RANGE 5% to 95% Non-condensing
  • SENSORS CO, H2S – Electrochemical sensor technology
  • SENSOR MEASURING RANGES Gas Type Range Resolution T90 CO 0-1000 ppm 1 ppm ≤10s CO 0-2000 ppm 1 ppm ≤10s H2S 0-100 ppm 0.1 ppm ≤10s H2S 0-200 ppm 0.1 ppm ≤10s H2S 0-500 ppm 0.1 ppm ≤10s
  • BATTERY 3.6 V Primary Lithium-thionyl chloride (Li-SOCl2), 1.5AH, 2/3AA , replaceable
  • RUN TIME Up to two years of runtime, depending on operating conditions, the amount of time the unit is in alarm, and the use of the unit's confidence indicator.
  • CERTIFICATIONS

International:

IECEX: Ex ia IIC T4 Ga; Ex ia I Ma

North America: UL: Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, AEx ia IIC T4 Ga CSA: Ex ia IIC T4 Class I, Division 1, Groups A, B, C, D T4

Europe: ATEX: Ex ia IIC T4 Ga; Ex ia I Ma CE: Directive 2014/30/EU, EN50270 Directive 2011/65/EU and 2015/863/EU

China: China Ex: Ex ia IIC T4 Ga China MA: Ex ia I Ma China CPA